Euroflo Products water pumps

















- HIRE PRODUCT
- PRODUCT SPECIFICATION PDF
- USED PUMPS PRODUCT
2″ Drainage Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Grindex Micro | 110V/240V | 0.4 | 10 | 4 | 8m @ 8m³/h | 11.5 | Manual | ||
| Auto | |||||||||
| Grindex Milli | 110V/240V | 0.4 | 11 | 3 | 8m @ 6m³/h | 6.2 | Manual | ||
| Auto | |||||||||
| Grindex Mini | 110V/240V | 0.9 | 15 | 6 | 12m @ 11m³/h | 11.5 | Manual | ||
| Auto | |||||||||
| Minex 1-phase | 240V | 1.4 | 18 | 10.5 | 14m @ 19.5m³/h | 7.5 | Manual | ||
| Auto | |||||||||
| Minex 3-phase | 400V | 1.2 | 17 | 10 | 13m @ 18.5m³/h | 7.5 | Manual | ||
| Auto | |||||||||
| Minex Lite | 110V/240V | 0.85 | 15 | 8 | 10m @ 14m³/h | 7.5 | Manual | ||
| Auto |
3″ Drainage Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Minette 1-phase | 240V | 1.5 | 18 | 15 | 13m @ 27.5m³/h | 9 | Manual | ||
| Auto | |||||||||
| Minette 3-phase | 400V | 2.2 | 22 | 17 | 16m @ 30m³/h | 9 | Manual | ||
| Auto | |||||||||
| Minor H | 240V/400V | 3.7 | 38 | 17 | 25m @ 32m³/h | 10 | Manual | ||
| Major H | 400V | 5.6 | 47 | 20 | 30m @ 36m³/h | 10 | Manual | ||
| Master SH | 400V | 10 | 80 | 18 | 62m @ 9m³/h | 10 | Manual |
4″ Drainage Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Minor N | 400V | 3.7 | 21 | 33 | 14m @ 63m³/h | 10 | Manual | ||
| Major N | 400V | 5.6 | 28 | 38 | 18m @ 72m³/h | 10 | Manual | ||
| Master H | 400V | 10 | 58 | 32 | 38m @ 16m³/h | 10 | Manual | ||
| Matador H | 400V | 18 | 70 | 45 | 46m @ 22.5m³/h | 12 | Manual | ||
| Maxi H | 400V | 37 | 95 | 70 | 78m @ 93.5m³/h | 12 | Manual | ||
| Maxi H Lite | 400V | 25 | 75 | 60 | 50m @ 108m³/h | 12 | Manual | ||
| Maxi SH | 400V | 37 | 140 | 38 | 105m @ 68.5m³/h | 12 | Manual | ||
| Mega H | 400V | 90 | 200 | 58 | 170m @ 108m³/h | 10 | Manual |
6″ Drainage Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Master N | 400V | 10 | 38 | 55 | 22m @ 101m³/h | 10 | Manual | ||
| Matador N | 400V | 18 | 40 | 95 | 24m @ 171m³/h | 12 | Manual | ||
| Magnum H | 400V | 57 | 100 | 70 | 85m @ 117m³/h | 12 | Manual | ||
| Mega N | 400V | 90 | 98 | 155 | 70m @ 284m³/h | 10 | Manual |
8″ Drainage Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Maxi N | 400V | 37 | 48 | 155 | 30m @ 279m³/h | 12 | Manual | ||
| Maxi L | 400V | 30 | 22 | 245 | 18m @ 450m³/h | 12 | Manual | ||
| Magnum N | 400V | 57 | 50 | 150 | 38m @ 270m³/h | 12 | Manual |
10″ Drainage Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Magnum L | 400V | 57 | 25 | 350 | 18m @ 630m³/h | 12 | Manual |
| Stainless Steel INOX Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Minette Inox | 240V/400V | 2 | 17 | 17 | 12m @ 31.5m³/h | 7.5 | Manual | Request Quote | |
| Major H INOX | 400V | 6.3 | 42 | 19 | 28m @ 36m³/h | 8.5 | Manual | Request Quote | |
| Master H INOX | 400V | 8 | 65 | 18 | 45m @ 36m³/h | 8.5 | Manual | Request Quote | |
| Major N INOX | 400V | 6.3 | 24 | 43 | 16m @ 75.5m³/h | 8.5 | Manual | Request Quote | |
| Master N INOX | 400V | 8 | 27 | 53 | 18m @ 94m³/h | 8.5 | Manual | Request Quote | |
| Mega N INOX | 400V | 85 | 98 | 145 | 75m @ 255m³/h | 10 | Manual | Request Quote | |
| Mega H INOX | 400V | 85 | 200 | 62 | 160m @ 108m³/h | 10 | Manual | Request Quote |
| Grindex Sludge Pumps | Voltage | Power (kW) | Max Head (m) | Max Flow (l/s) | Optimal Capacity | Solids Passage (mm) | Type | Data Sheet | Weekly Rate |
|---|---|---|---|---|---|---|---|---|---|
| Solid | 110V/240V | 0.9 | 12 | 7 | 8m @ 12.5m³/h | 38 | Manual | ||
| Auto | |||||||||
| Salvador 1-ph | 240V | 1.5 | 14 | 12 l /s | 7m @ 21m³/h | 50 | Manual | ||
| Salvador 3-ph | 240V/400V | 2.2 | 16 | 14l /s | 10m @ 25m³/h | 50 | Manual | ||
| Senior | 240V/400V | 3.2 | 9 | 24 | 8m @ 42.5m³/h | 80 | Manual | ||
| Sandy N | 240V/400V | 5.6 | 28 | 17 | 22m @ 30m³/h | 46 | Manual | ||
| Sandy H | 240V/400V | 5.6 | 40 | 8 | 35m @ 14m³/h | 32 | Manual | ||
| Salvador INOX | 400V | 2 | 14 | 14 | 7m @ 24m³/h | 50 | Manual | ||
| Senior INOX | 400V | 4.1 | 9 | 35 | 7m @ 62m³/h | 80 | Manual | ||
| Sandy INOX | 400V | 6.3 | 24 | 16 | 18m @ 29m³/h | 46 | Manual |
Product Specifications PDF